SystemSURE Plus

$1,595.00

SystemSURE Plus™ is the next-generation system of the world’s best-selling SystemSURE II ATP hygiene monitoring system. With improved functionality, new software, and increased memory, the SystemSURE Plus meets the demands of the largest and smallest companies around the world.

Category:

Key Benefits

Superior Performance

Better Design

Complete Hygiene Monitoring Platform

Superior Performance

The data speaks for itself. The most comprehensive evaluation of ATP hygiene monitoring systems has been completed by one of the world’s premier food and beverage reference laboratories. They evaluated these four key areas of performance.

Linearity

The linearity graph shows a direct, proportional, straight-line relationship between RLU and ATP for the Hygiena™ system. The closer to linear a system can get, the more precise and reliable the results will be. Systems that deviate from linear offer less reliable results and less sensitivity. The data in the graphic demonstrates the Hygiena™ system is among the most linear on the market.

Repeatability

Repeatability is described by Coefficient of Variation (CV). The higher the CV, the greater the variability between each result with the same sample. More variability means the results are more inconsistent and unreliable. The graph shows that Hygiena™ systems consistently deliver dependable results with the lowest CV.

Sensitivity

Sensitivity is defined as the Limit of Detection (LoD). It is the smallest amount of ATP detectable above the background noise of the system. Background noise is the RLU detected by the system in the absence of ATP. Background noise may come from both the instrument (as electrical interference), and the reagent swab device (as chemical interference). Hygiena™ systems detect the lowest levels of ATP.

Accuracy

To test accuracy, 100 fmoles of ATP was added to each test device and measurements were taken (using 10 replicates) to determine how much of the available sample was actually detected. Results less than 100% indicate that only part of the sample was detected due to some interference within the system. Results over 100% indicate extra signal coming from the test device. Hygiena’s system is the closest to 100%, thus the least variable.

Better Design

Every feature of the SystemSURE Plus™ monitoring system was built with you, the customer in mind and to meet the demands of your facility.

Battery Power for Months

The SystemSURE Plus™ runs on two AA batteries providing long battery life so you don’t have to worry about charging the unit every day. You can expect up to 8-12 months of uninterrupted use before needing to change the batteries. Replacement batteries are very affordable, while other systems use batteries that are expensive to replace and only last 6-8 hours with a minimum charge time of 2 hours.

Better technology in a smaller box.

The SystemSURE Plus™ uses state-of-the-art Photodiode (PD) sensor technology that provides superior sensitivity and stability over fragile and bulky photomultiplier tube (PMT) sensors. The small, thin and sleek design of the photodiode has several advantages over PMT. They’re more durable and more energy-efficient.

Removable Read Chamber

Unique to the SystemSURE Plus™ is the removable read chamber, which makes cleaning easy. The demands of some facilities can commonly lead to contaminated read chambers. Other manufacturers require you to ship your system back if the read chamber becomes contaminated, resulting in costly repairs and delays. Hygiena’s system is designed so you can quickly clean the read chamber, reducing downtime and saving money.

Maximum Durability

The SystemSURE Plus™ has a durable outer shell and keypad are meant to last. The splash-proof keypad won’t let moisture in and the robust outer shell is sturdy to withstand the shock of minor drops and years of use.

Designed For One Hand Use

Even when you already have your hands full, the sleek design of SystemSURE Plus™ makes scrolling and selecting test locations a breeze. It is completely operable with one hand, making your life that much easier. Dimension are 3″ x 7″ x 1″ (7.6cm x 17.8cm x 3cm).

Work Hands-free Wherever You Go

Each SystemSURE Plus™ comes with a complimentary protective carrying case and shoulder strap so you can work hands-free wherever you go. The carrying case and shoulder strap minimize potential drops to keep your device safe while on the go. In addition, the carrying case comes with a zipper pouch for convenient storage of swabs, instructions, notes, or any other essentials.

Verify Calibration at Your Convenience

With built-in sensor checks and a Calibration Control Kit sold separately, verifying calibration is literally effortless. Simply turn on the self-check feature and every time the system is powered on, calibration will be confirmed. If your HACCP or GMP program calls for additional calibration assurance, use the Calibration Control Kit to verify the system is in working order at any time. With the internal self-check and the calibration kit, you’ll always be confident the system is within specifications. In addition, you’ll avoid costly and inconvenient yearly calibration charges that other manufacturers require.

Complete Environmental Monitoring Solution

Our Hygiena™ monitoring systems are designed to be a complete environmental monitoring solution. We’ve combined an intuitive luminometer interface with compatibility across all Hygiena’s test devices. Use our best-in-class ATP test devices to verify cleanliness. Go deeper and use our MicroSnap™ indicator organism tests to isolate problem areas in your facility. Need to test for glucose, lactose, or other enzymes? We’ve got you covered. Learn more about all our tests below.

Reviews

There are no reviews yet.

Be the first to review “SystemSURE Plus”

Your email address will not be published. Required fields are marked *

SystemSURE PlusSystemSURE Plus
$1,595.00